This summary of air compressor restart preparations for resuming work is intended to ensure a safe and smooth restart of your compressor. It contains key operating points and precautions. We hope this guide will help you resume work smoothly.
Before starting up
1. Electrical and wiring inspection: Check that wiring connections are secure and free of damage or short circuits; measure the motor insulation resistance.
2. Lubrication system inspection: Check that the oil level is between the oil dipstick marks. If the machine has been down for an extended period, it is recommended to replace the lubricating oil and oil filter.
3. Control system and valve inspection: After powering on, check that the controller display is normal. Confirm that the exhaust valve is fully open.
4. Cooling system preparation: Start the cooling water circulation system of the water-cooled unit to ensure it is unobstructed. Inspect the radiator of the air-cooled unit and clean any dust.
5. Intake inspection: Clean or inspect the air filter to prevent blockage.
6. Pipe inspection: Check all pipe connections for leaks.
Startup
1. Critical step: Before officially starting up, perform a jog operation. This helps establish oil circulation and prevent dry running of the engine head.